Products and Services » betagauge
betagauge

 

FH62I-N Beta Attenuation Monitor

Andersen Instruments Beta Gauge is the most advanced system for automatic, continuous, and accurate ambient articulate sampling. Model FH621-N is the only beta gauge that utilizes a truly continuous 60 minute to 24 hour sampling cycle, eliminating a step-wise response to move the filter. The system is also insensitive to vibration and does not require frequent visits to change the filter. The Krypton 85 radiation source is contained in a stainless steel capsule, where the Beta energy makes it possible to measure even large mass values of particles on the filter. The system can stand alone in an outdoor shelter or used indoors due to its sensitivity to changes of ambient temperature, pressure conditions, and humidity. This accuracy is achieved by a unique dual beam two detector principle. Andersen's Beta Gauge does not require a user's radiation license.
The Andersen FH621-N Beta Gauge Sampler is designed to continuously measure the mass concentration of PM 10 particles in ambient air. The beta gauge sampler is EPA approved for continuous PM 10 compliance monitoring and is also used extensively for Pollutant Standard Index (PSI) networks. The FH621-N is the only beta gauge sampler that can be directly calibrated in the field with a set of calibration control foils and the only beta gauge sampler that collects and measures at a single filter-spot position. The sampler also does not heat the measurement chamber which, if heated, can drive oft volatile particles and cause errors in measurements. A complete FH621-N Beta Gauge consists of three main components: the central instrument, pump, and SA246B PM 10 inlet. The central instrument includes filter strip mechanism, radiation measuring chambers, LCD display with control keys, and the complete electronic circuitry.

Features

  • Low maintenance and low operating costs
  • Approved EPA Equivalent Method Designation (EQPM-0990-076)
  • Accurate PM 10 measurement for both EPA 24-hour averages and hourly episode studies
  • Low detection limit and high accuracy
  • Determination of mass concentration is independent of particle shape, color and size available as TSP, PM 10, or PM 2.5

SA246B PM-10 Inlet

Suspended particles in ambient air enter the 10 micron inlet at a flow rate of 16.7 LPM (1CMH). The parallel plate inlet, insect screen, and conical flow deflector yield accurate sampling independent of wind speed and precipitation. Air is drawn into the inlet and deflected downwards into the acceleration jet of the impactor unit. By virtue of their greater momentum, particles larger than the 10 micron cut-point impact out and are retained in the middle plenum impaction chamber. The particle fraction smaller than 10 microns is carried vertically upward by the air flow and down the vent tubes to the beta gauge sampler. (PM2.5 and TSP inlets am also available).

Principle of Beta Attenuation

Ambient air is pulled through the PM 10 sample inlet and dust particles are deposited on the glass fiber filter tape. A low level of beta radiation is emitted from the source which passes through the filter tape and deposited dust. The increase of particles collected on the tape causes a lower beta-ray measurement in the measuring chamber. Them is direct mass collection and simultaneous measurement at this single filter-spot position which results in continuous observation of the Increasing dust mass and corresponding concentration. A compensation chamber receives an equal portion of the beta-ray and is used as a reference by comparing the sample measurement In the measuring chamber with transmitted energy through a compensation chamber foil which exhibits the same absorptivity as a clean filter tape. As particulate matter is collected on the filter, the differential reading changes and the signal is converted by an on-board computer to PM 10 concentrations. Ionization chamber are used as radiation detectors because of their excellent temperature stability and practical unlimited life time. Output from the instrument can be through visual display1 on board computer, telemetry, printout, or storage in an auxiliary disc.

Specifications

r
Measuring Principle Direct mass collection and simultaneous measurement by a dual beam compensation method and single filter-spot position. (No step-wise response with preselected time and range intervals)
Type of Basic Output Function Integral function mass over time (continuously observed)
Measuring Range 5 to 10,000 ?g/m 3 ; peaks up to 20,000 ?g/m 3
Minimum Detectable Limit Less than 2 ?g/m 3 (24 hr)
Accuracy 2 ?g/m 3 (24 hr)
Measurement Cycles Continuous observation of the increasing dust mass during sampling (not step-wise). The time of full load of filter in which one single filter spot remains in the same position is: Ambient concentration of 50mg/m 3 : 24 hr at (1 ?g/m 3 ) flowrate
Output Signals 0-10 V for concentration and mass over time
Optional Output Signals 0-20 mA: 2-20 mA; 4-20 mA (life zero)
PrinteriComputer Interface V24/RS232 C serial interface
Scanning Time 5 sec. 4 mm. (automatically)
Air Flow Rate 1 m 3 /h
Flow Rate Regulation Intemal (PI-type)
Stability of Flow Rate +/- 0.3% with regulator
Operating Temperature -10?C to +50?C
Pump Type Rotary vane pump with carbon vanes
Time Between Calibration Checks and Maintenance 4 months (automatic zero during running)
Type of Calibration Checks Set with 2 mica foils (zero and span/mass)
Filtering System Glass fiber filter tape (width: 40mm; length: 30m)
Consumable Materials Per Year 1 set of carbon vanes for pump 1; 2 filter tapes
Sampling Heads (Inlets) -TSP (1 m 3 /h) total suspended particulate
-PM 10(1 m 3 /h). Inhalable particulate 10 ?m
Microprocessor Controlled PC Connection, Auto Calculation, Data Storage, Built-in Diagnostics
Status Signals Filter Break, Air Flow, Zero Adjustment, Filter Change, 2 Alarms
Power Supply 110v/50-60 Hz or 220v/50/60 Hz

Models

The FH621-N PM 10 Beta Attenuation Particulate Monitor, 110v/60Hz includes:

FH621 19" Rack Mount Beta Monitor
SA246B PM 10 Inlet
FH102 Accessory Kit. Includes:(2) FH111-2 Filter Tape Rolls & Hardware
FH107 Roof Flange Kit. Includes: FH122 - Flat Roof Mounting Flange
FH120 72" Drift Tube to connect Beta Monitor to Roof Flange
FH118 22" Inlet Tube to connect Roof Flange to Inlet
FH104 D.O.T. Shipping Crate

The FH621-NOP1(Indoor) model also comes with an indoor 19" cabinet

The FH621-NOP2(Outdoor) model also comes with an outdoor weather enclosure

Note: For U.S. EPA Equivalent Method Designation FM125 Calibration Mass Foil Kit is required. One calibration kit can be used on multiple units.

FH125 Calibration Kit - Calibration Mass Foil