Land Model 6500 Portable Analyzer
The Land unit utilizes electrochemical cell technology to analyze
flue gases for multiple products of incomplete combustion. Besides measuring
for several gaseous pollutants, the unit also measures exhaust gas temperature
and calculates combustion efficiency. With such features as an on-board
printer, RS232 connector and on-screen calibration functions, the Land
portable combustion analyzer is ideal for quick, reliable gaseous pollutant
determinations.
 |
Parameter
Range
02
0 - 25%
CO
0 - 2,000 / 40,000 ppm
NO
0 - 1,000 ppm
NO2
0 - l00 ppm
THC
0 - 50,000 ppm
Temperature
0-999o C / 1832o F
|
Testo 350 Portable Analyzer
The Testo unit is almost identical in operation to the Land unit except
that it replaces the THC sensor for an S02 sensor. The Testo unit has a
portable printer and an RS-232 connector. Data can be downloaded to a computer
if coupled with Testo Software.
| Parameter
Range
O2
0 - 20.9%
CO
0 - 10,000 ppm
NO
0 - 3,000 ppm
NO2
0 - 500 ppm
SO2
0 - 5,000 ppm
Temperature
0 - 999o C / 1832o F
|
Helpful Hint:
The Testo has a rechargeable battery which
provides up to 8 hours of continuous use. The
provided probe will handle temperatures up to
1,500o F. |
Telegan Tempest 100 Portable Analyzer
The Telegan unit is the most portable electrochemical cell instrument
that Cherokee provides. The small size, lightweight, and excellent functionality
make this instrument ideal for multiple location pollutant surveys. The
Telegan is provided with an on-board printer; RS-232 connector and on-screen
calibration functions.
 |
Parameter
Range
02
0 - 25%
CO
0 - 4,000 ppm
NO
0 -1,000 ppm
NO2
0 - 200 ppm
SO2
0 - 2,000 ppm
Temperature
0 - 800o C
/ 1472o F
|
ECOM - AC Portable Analyzer
The Ecom - AC is a suitcase style portable analyzer using fuel cell
technology for pollutant detection. The Ecom features an on-board printer;
RS232 connector and on-screen calibration functions. Data can be downloaded
to a computer if coupled with Ecom Software.
 |
Parameter
Range
O2
0 - 21%
CO
0 - 4,000 ppm
NO
0 - 4,000 ppm
NO2
0 - 500 ppm
Temperature
0 - 800o C / 1472o F
Helpful Hint:
The Ecom has a rechargeable battery which
provides up to 8 hours of continuous use.
The probe will handle temperatures up to
1500o F. Longer probes (up to 6 ft.)
are
available. |
|