Product Lines » AMP-Cherokee » noxanalyzers
noxanalyzers

CEM Monitors - Rental Equipment

API Model 200AH Oxides of Nitrogen Analyzer The API Model 200AH NO/NO2/NOx analyzer uses the analytical technique of chemiluminescence.
The instrument is microprocessor and can simultaneously output NO,NO2, and NOx concentrations.
The has an internal high temperature convertor and calculates NO2 to NO conversion efficiency
real-time. The provided vacuum pump provides vacuum for the reaction chamber and filtered air
for ozone generation. Ranges are user defined from 5 to 5,000 ppm.

Manufacturer Advanced Pollution Instrumentation (API)
Analysis Method chemiluminescence
Range 0 - 5,000 ppm
Range Mode ppm or mg/m3, single range, auto
range, remote range, range control
independent NO, N02, NOx
Zero Noise 20 ppb rms
Span Noise < 2% of reading
Zero Drift < 20 ppb / 24 hrs.
Span Drift < 1 % of reading / 24 hrs..
Lag Time < 20 secs. switching mode, < 6 secs.
NO or NOx only mode
Rise / Fall (95%) 60 secs. switching mode
10 secs. NOx only mode
5 secs. NO only mode
Sample Flow Rate 290 cc/minute
Analog Output 0 - 100 mV, 1, 5, 10 VDC and 4
to 20 mA
Power 115 VAC
Dimensions 17" by 7" by 23.5"
Weight 44 lbs.


API Model 252 Oxides of Nitrogen Analyzers

The API Model 252 NOx analyzer uses the analytical technique of chemiluminescence. The instrument is coupled with an internal molybdenum convertor and can be coupled with an
external stainless steel convertor. The vacuum pump provides vacuum for the reaction chamber
and filtered air for ozone generation. Three selectable ranges can be chosen. Dilution - Extractive
Range Instruments are available.

Manufacturer Advanced Pollution Instrumentation (API)
Analysis Method Chemiluminescence
Range 0 - 50, 100, 1000, or 0-100, 1000, 2500 ppm
Noise < 1% of reading
Zero Drift < 0.2 % of reading
Span Drift < 2 % of full scale
Sample Flow Rate 250 cc /minute
Analog Output 0 - 5 VDC
Power 115 VAC
Dimensions 17" by 7" by 22"
Weight 56 lbs.

California Analytical Model 300CLD Oxides of Nitrogen Analyzer

The California Analytical Model 300CLD NO / NO2 / NOx analyzer uses the analytical technique of chemiluminescence. The instrument, unlike most other NOx analyzers, requires positive pressure
for the sample and is supplied with a positive pressure pump. Response times are extremely fast yet an external air supply is needed for ozone generation. Multiple ranges are available from 100 ppm to 10,000 ppm.

Manufacturer California Analytical Instruments
Analysis Method Chemiluminescence
Range 100 to 10,000 ppm
Response Time Adjustable from 1.5 to 10 secs.
to 90 % of full scale
Noise < +/- 0.5 % of full scale
Zero and Span Drift < 1 % of full scale in 24 hrs.
Sample Flow Rate 2 litre /minute
Analog Output 0 - 10 VDC and 4 to 20 mA DC
Power 115 VAC
Dimensions 5 1/4 " by 19" by 20 "
Weight 38 lbs.


Service Note: The California Analytical NOx Analyzer requires the use of an external air source for ozone generation. If you expect NOx concentrations above 2,000 ppm, an oxygen source is needed for proper operation.